It is a vertical pipe attached to a drain line and runs through the roof of your home.
Vent stack thru roof deck.
Open vent pipes that extend through a roof shall be terminated at least 6 inches 152 mm above the roof or 6 inches 152 mm above the anticipated snow accumulation whichever is greater except that where a roof is to be used for any purpose other than weather protection the vent extension shall.
A stack vent is the extension of the waste stack to provide venting.
You can connect the kitchen vent to the main vent in the attic as long as the main vent is the proper size and extends through the roof.
Set your store to see local availability add to cart.
The main stack is the heart of the venting system.
Our tampa plumbers note that the functions of a stack vent.
Inside diameter black new construction or reroof thermoplastic vent pipe roof flashing model pb 312 4bk 19 97 19 97.
All open vent pipes that extend through a roof shall be terminated at least number typically 6 inches mm above the roof except that where a roof is to be used for any purpose other than weather protection the vent extensions shall be run at least 7 feet 2134 mm above the roof.
Oatey galvanized no calk flashing 3 in x 14 5 in galvanized steel vent and pipe flashing.
Supervent 6 in x 24 in.
Roof flashing model 14056 62 40 62 40.
All the vents connect to it through branch lines and it vents the main toilet the most important plumbing fixture in most houses.
Why plumbing air vents are important.
It channels the exhaust gases to the vent and helps maintain proper atmospheric pressure in the waste system.
The uppermost part of the waste stack that connects to the uppermost part of the roof is the stack vent.
Oatey master flash 6 in.
If the attic space is going to be conditioned either for living or mechanical purposes or if a home design calls for a vaulted ceiling provision r806 3 in the international residential code calls for the roof deck above the space to be vented continuously from the eave to the ridge.
The stack has to run the most direct route through open air or be ventilated to extend to open air.
Vent the roof deck.
Free delivery with 45 order.
For pricing and availability.
6 minimum or 6 higher than snow accumulation for the geographic area.
Oatey retro master roof flashing 1 4 in to 4 in x 8 in epdm rubber vent and pipe flashing.
Drainpipe serving a single family home needs a main vent that is at least 1 1 2 in.
Above roof plumbing vent diameter.
If you can t put the main stack through the roof most local plumbing codes allow you to put it through a wall instead but there are conditions.