The large leg of the metal goes against the wall leaving the seat and face covering the top edge of the siding.
Z flashing hardie siding.
Please see your local james hardie dealer for.
It is used to protect the horizontal joints between sheets of siding from water infiltration.
Galvanized steel z flashing is made from 28 gauge galvanized steel.
Thick and is available in 4x8 4x9 and 4x10 sizes.
It is used to protect the horizontal joints between sheets of siding from water infiltration.
Product overview galvanized steel z flashing is made from professional 31 gauge galvanized steel.
The seat dimension 3 8 in corresponds to the siding thickness.
Hardiepanel vertical siding is factory primed fiber cement vertical siding available in a variety of sizes and textures.
Galvanized steel z flashing is made from 28 gauge galvanized steel.
Do not caulk clearance and flashing requirements hardiepanel vertical siding hs1237 p2 3 09 19 figure 10 sheltered areas figure 11 mortar masonry min.
The seat dimension 3 4 in corresponds to the siding thickness.
The large leg of the metal goes against the wall leaving the seat and face covering the top edge of the siding.
Used over window trim band boards panel intersections and other vertical surfaces.
It is used to protect the horizontal joints between sheets of siding from water infiltration.
Out from the fascia when gutters are present as required by irc code min 4 in.
Z bar flashing provides an inexpensive and easy to install method of stopping water penetration behind siding.
Luckily it takes lots of water to saturate hardie products.
The large leg of the metal goes against the wall leaving the seat and face covering the top edge of the siding.
If your contractor installs hardie siding when it s saturated it may show signs of shrinkage or even staining over time.
Z flashing z flashing z flashing min.
Item 3807 model 5504900120.
Window and door cap 1 25 in x 120 in x 1 56 in aluminum z flashing.
Textures include smooth stucco cedarmill and sierra 8.
Flush the end of the flashing length with the wall corner and secure the flashing to the framing with an 8d nail at each wall stud.
Examples of these are shown below.
Do not caulk extend shingles at least 1 in.
Begin at either end of the wall and set the level middle section of the z flashing onto the top edge of the siding panel with the wider flange upward and against the wall framing.
Product detail design features z flashing provides an easy to install and long lasting method of stopping water penetration.